PRODUCT RESOURCES

TRÜbath Technical Data

Shower pans, component references and the details that matter for your project.

Reviewed November 5, 2026

Match the evidence to the product.

A component listing or material test applies to its identified product and tested construction. It does not automatically certify a completed TRÜbath shower-pan assembly. Confirm the selected base, porcelain, finish, drain and installation system before fabrication.

Manufacturer component listing

Shower-base reference: PMG-1194

Original issuer
ICC Evaluation Service, LLC (ICC-ES)
Listed manufacturer
KBRS Inc.
Products identified
KBRS Tile-Basin®, Vanity Vessel™ and ShowerSlope™
Document date
Effective June 2026; subject to re-examination in one year
Standards identified
ANSI/TCNA A118.10-2023; ASTM C627-2018 (R2024); CSA B45.5/IAPMO Z124-2022; IAPMO PS 106-2015e1

The listing addresses the identified manufacturer components. Its ASTM C627 floor-system result used standardized 8 × 8 inch tiles; it is not a test of every porcelain-clad TRÜbath configuration.

Application: Use only when the supplied component is covered by the listing and installed to the manufacturer’s instructions and applicable codes. Project-specific cladding, adhesive, drain and field waterproofing still require review.

Read the original ICC-ES listing (PDF) ↗
Product specification review

Porcelain surface and finish

Confirm the exact manufacturer, product code, finish and thickness. ANSI A137.3 addresses gauged porcelain tiles and panels/slabs; ANSI A137.1 addresses ceramic tile, including porcelain. The applicable category depends on the selected product.

Porcelain classification uses water absorption of 0.5% or less under ASTM C373. This is a classification criterion, not a published measurement for every finish shown on this website.

Shower-floor suitability: A DCOF result belongs to its tested specimen and method. It does not establish slip resistance or safety for every finished shower pan, wet-barefoot condition, slope or maintenance condition. Product-specific evidence and manufacturer suitability confirmation are required.

TCNA gauged-porcelain standards overview ↗ANSI porcelain classification overview ↗
Project submittal checklist

Before ordering or installing

Composite wall-panel mechanical or fire tests are not evidence of shower-pan performance. Original reports retain their original issuer, client and specimen identity. This page does not reproduce restricted laboratory reports or claim a finished-assembly certification.